Optimized Demagnetization Control Strategy of Double Feed Induction Generator in Fault Ride Through Period
编号:254
访问权限:仅限参会人
更新:2020-11-11 12:10:16 浏览:150次
张贴报告
摘要
In fault ride through (FRT) period, the stator side of double feed induction generator (DFIG) will generate a transient flux, which may cause the rotor overcurrent and the DC bus over voltage. The demagnetization control is an effective method to accelerate the decay of stator transient flux. But the effect of traditional demagnetization control is not ideal. In this paper, the transient model of DFIG is derived first. Then, an optimized demagnetization control strategy is proposed, and the performance of the proposed strategy is analyzed. The simulation results of a 2 MW DFIG system in DIgSILENT/Power Factory software validate that
the optimized demagnetization control strategy can accelerate the decay of stator transient flux more effectively than the traditional demagnetization control strategy.
关键词
DFIG,Demagnetization Control,FRT,Rotor Transient Current,Stator Transient Flux
稿件作者
Jianjian Xu
Shan Dong University
Lei Ding
Shan Dong University
Xuesong Gao
Shan Dong University
发表评论