Wavelength shifters for optically read out MPGDs
编号:41 访问权限:仅限参会人 更新:2024-10-09 14:11:53 浏览:299次 口头报告

报告开始:2024年10月15日 12:05(Asia/Shanghai)

报告时间:25min

所在会场:[M2] MPGD2024-Day2 [Day 2-1] MPGD2024-Day2AM

演示文件

提示:该报告下的文件权限为仅限参会人,您尚未登录,暂时无法查看。

摘要

Optical readout of MPGDs achieves high spatial resolution with state-of-the-art pixellated imaging sensors for applications ranging from optical Time Projection Chambers (TPCs) to imaging and detector characterisation. Gas mixtures containing CF4 are the most popular choice for optically read out MPGDs due to their strong visible light yield. This presents challenges due to decreasing availability of CF4 and its classification as greenhouse gas and limits the usability of optical readout. Alternative approaches include the use of UV-sensitive imaging sensors or the use of wavelength shifting to convert light to a wavelength range compatible with the sensitivity of readout devices.

We present studies of solid wavelength shifters including Tetra-Phenyl-Butadiene (TPB) and PolyEthylene Naphthalate (PEN) layers which were used to convert secondary scintillation light in the (V)UV range to visible light. The re-emission of both materials is compatible with conventional imaging sensors. In comparison, TPB achieves higher conversion efficiency, while PEN is readily available and may be advantageous for integration into detectors due to its higher robustness.

Spectroscopic measurements are performed to confirm re-emission from wavelength shifting layers. The achievable spatial resolution of GEM and Micromegas detectors combined with semi-transparent wavelength shifting layers deposited on right substrates to enable optical readout is studied. X-ray radiography is used to quantify the effect of the separation of amplification stage and wavelength shifter spatial resolution. The deposition of a wavelength shifting layer on the anode in a bulk glass Micromegas detector minimises blurring and yielded the best results with spatial resolution comparable to the case of direct readout of CF4-based gas mixtures.

Operation in pure noble gases with wavelength shifters coupled to (M-)THGEM detectors is studied which extends the versatility of the optical readout approach for TPCs and reduces limitations on gas mixture composition.

关键词
optical readout,wavelength shifter,scintillation,GEM,Micromegas,spatial resolution
报告人
Florian Maximilian Brunbauer
Dr. CERN

稿件作者
Florian Maximilian Brunbauer CERN
Antoine Cools IRFU, CEA, Université Paris-Saclay
Marco Cortesi Facility for Rare Isotope Beams, Michigan State University
Esther Ferrer-Ribas IRFU, CEA, Université Paris-Saclay
Karl Jonathan Flöthner CERN;University of Bonn
Francisco Garcia Helsinki Institute of Physics
Djunes Janssens CERN
Marta Lisowska CERN
Hans Muller CERN
Juha Nummi Helsinki Institute of Physics
Eraldo Oliveri CERN
Giorgio Orlandini Friedrich-Alexander-Universität Erlangen-Nürnberg;CERN
Thomas Papaevangelou IRFU, CEA, Université Paris-Saclay
Dorothea Pfeiffer European Spallation Source ERIC (ESS)
Emmanuel Pollacco IRFU, CEA, Université Paris-Saclay
Leszek Ropelewski CERN
Jerome Samarati European Spallation Source ERIC (ESS)
Lucian Scharenberg CERN
Miranda Van Stenis CERN
Ron Veenhof CERN
发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    10月13日

    2024

    10月18日

    2024

  • 10月18日 2024

    报告提交截止日期

  • 10月31日 2024

    初稿截稿日期

  • 01月31日 2025

    注册截止日期

主办单位
University of Science and Technology of China
移动端
在手机上打开
小程序
打开微信小程序
客服