基于磷酸镁无机胶作胶粘剂的CFRP加固混凝土梁抗火性能研究
编号:122 访问权限:仅限参会人 更新:2025-04-23 11:33:33 浏览:18次 口头报告

报告开始:2025年05月17日 16:30(Asia/Shanghai)

报告时间:10min

所在会场:[P] 5月17日下午分会 [P10] 10. 工程结构抗火抗爆理论与对策

演示文件

提示:该报告下的文件权限为仅限参会人,您尚未登录,暂时无法查看。

摘要
The fire safety of CFRP-strengthened concrete structures has raised much concern due to the sensitivity of epoxy-based bonding agents to high temperature and failure of strengthening system. Hence, replacing traditional epoxy adhesives with the inorganic adhesives with better high-temperature resistance provides a chance to improve the safety of the strengthened concrete structures under fire. At present, there are few studies concerning the fire behavior of the concrete beams strengthened with the CFRP sheets using magnesium phosphate inorganic adhesive (MPIA) as adhesive agent, and the failure mechanism of the CFRP-MPIA strengthening system under fire is unknown. To fill this gap, eleven specimens were designed and fabricated in this study, and the standard fire tests under constant load were carried out. During tests, the fire responses of the specimens, including the temperature and mid-span deflection developments, the failure time of strengthening system, fire resistance, and failure mode were measured and analyzed. Also, the effect of load level, adhesive type and fire insulation on the fire resistance of the strengthened concrete beams was investigated. The results showed that the MPIA, served as bonding agent, possesses excellent high-temperature resistance, and the “binder-CFRP sheet-binder” sandwich design can thus play a role of thermal insulation for CFRP sheets, which postpones the failure time of CFRP-MPIA strengthening system effectively, and the excellent mechanical properties of the CFRP sheets under anoxic conditions can also be fully utilized. These make the fire resistance of the CFRP-MPIA strengthened concrete beams without fire insulation are slightly higher than those of the CFRP-epoxy strengthened beams with a fire insulation of 20 mm, achieving the integrated design goal of strengthening and fire resistance. Additionally, with the combined use of the fire insulation and the “binder-CFRP sheet-binder” sandwich strengthening system, the fire resistance of the CFRP-MPIA strengthened concrete beams are over 50 % higher than those of the CFRP-epoxy strengthened concrete beams.
 
关键词
CFRP加固混凝土梁;磷酸镁无机胶;热力学性能;火灾试验;耐火性能;防火保护
报告人
任鹏飞
副研究员 山东建筑大学

任鹏飞,哈尔滨工业大学工学博士,山东建筑大学副研究员,硕士生导师,主要研究方向为结构抗火、材料高温性能、既有结构加固与改造,主持国家自然科学基金青年基金1项、山东省自然科学基金青年基金1项、山东建筑大学博士科研基金1项,参与国家自然科学基金面上项目4项、山东省高等学校“青创团队”项目1项、黑龙江省优秀青年科学基金项目1项、教育部重点实验室开放基金项目1项;近5年发表SCI论文8篇(一区top期刊7篇、二区top期刊1篇)、北大中文核心期刊论文2篇、ISTP论文1篇;授权国家发明专利6项、软件著作权3项。
 

发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    05月16日

    2025

    05月18日

    2025

  • 04月15日 2025

    初稿截稿日期

  • 05月10日 2025

    报告提交截止日期

  • 05月18日 2025

    注册截止日期

主办单位
中国灾害防御协会
江苏省地震局
中国地震学会基础设施工程防震减灾专业委员会
兰州交通大学
承办单位
兰州交通大学土木工程学院
历届会议
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询